Gamma Solar PCU

The Gamma solar PCU (Power Conditioning Unit) is rMPPT offline solar PCU one phase in one phase out. It is very affordable for schools, hospitals, petrol pumps, industries, and buildinds and also for home. The Gamma Solar PCU (rMPPT) is uses the solar power energy in first priority and the government electricity (grid) in second priority to charge the solar batteries.

GAMMA PCU
GAMMA PCU

Usage of power energy from grid is secondary, grid power is only used when solar energy is not present and solar battery voltage level reduces to a certain level. Grid power is also needed when solar power is reduced to a certain level and battery voltage is reduced to a certain level.

Gamma solar PCU has the advance features like DSP base design built in MPPT solar charge controller, most advanced LCD features, maximum preference to solar power, smart PCU, capability of 100% solar panel rating, compatible with all PV arrays having different no. of cells (36 cell/60 cell/72 cell), lightning protection, high efficiency MPPT inverter.

This is available in various models range like Gamma solar PCU 2kVA/24V, Gamma PCU 2kVA/48V, Gamma solar PCU 3kVA/48V, Gamma PCU 5kVA/48V and Gamma solar PCU 5kVA/96V.

PCU Mode Priority - Solar/Battery/Grid

Hybrid Mode Priority - For Load - Grid/Solar/Battery for Charging - Solar/Grid

Smart Mode Priority - For Day Time - Solar/Battery/Grid for Night Time - Grid/Battery

Price of Gamma PCU

GAMMA PCU
GAMMA PCU
Models MRP ( Inclusive of all Taxes ) Discounted Price ( Inclusive of all Taxes )
Gamma 2KVA 24V Rs. 34,009 Rs. 31,600
Gamma 2KVA 48V Rs. 34,009 Rs. 31,600
Gamma 3KVA 48V Rs. 46,256 Rs. 42,979
Gamma 5KVA 48V Rs. 66,517 Rs. 61,808
Gamma 5KVA 96V Rs. 66,517 Rs. 61,808

Technical Specifications of Gamma PCU 1PH in 1PH out

2KVA 24V Gamma PCU

Description Particulars
Solar PCU Capacity 2KVA 24V
Input Voltage Range (min-max) 45-90 VDC
Maximum PV Power Recommended 2KW
Types of Charger PWM with MPPT
Charge Controller Peak Efficiency 95%
Battery Low Buzzer 10.2V
Battery Low Cut 10.0V
Battery High Cut 15.5V
Battery Charging Voltage by SPV 14.5V
Battery Charging Current by SPV 18A
Battery Charging Voltage by GRID 14.2V
Battery Charging Current by GRID 10A
Grid Low Cut Voltage ( IT Load Disable/Enable) 120/175V
Grid High Cut Voltage ( IT Load Disable/Enable) 280/255V
Inverter Nominal Output Voltage 230VAC
Output Supply Phase 1 phase, 3 wire
Output Waveform Sine wave
Nominal Frequency 50.0 HZ
Load Current 6.1 A
Inverter Peak Efficiency >88%
Protections Overload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display Parameters Battery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
Switches Reset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
Indications System ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing) 95%
Weight 30KG
Dimension (L X W X H) 457 X 254 X 431 mm
MRP Price ( Inclusive of all Taxes ) Rs. 34,009
Discounted  Price ( Inclusive of all Taxes ) Rs. 31,600

2KVA 48V Gamma PCU

Description Particulars
Solar PCU Capacity 2KVA 48V
Input Voltage Range (min-max) 80-230 VDC
Maximum PV Power Recommended 2KW
Types of Charger PWM with MPPT
Charge Controller Peak Efficiency 95%
Battery Low Buzzer 10.2V
Battery Low Cut 10.0V
Battery High Cut 15.5V
Battery Charging Voltage by SPV 14.5V
Battery Charging Current by SPV 18A
Battery Charging Voltage by GRID 14.2V
Battery Charging Current by GRID 10A
Grid Low Cut Voltage ( IT Load Disable/Enable) 120/175V
Grid High Cut Voltage ( IT Load Disable/Enable) 280/255V
Inverter Nominal Output Voltage 230VAC
Output Supply Phase 1 phase, 3 wire
Output Waveform Sine wave
Nominal Frequency 50.0 HZ
Load Current 6.1 A
Inverter Peak Efficiency >88%
Protections Overload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display Parameters Battery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
Switches Reset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
Indications System ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing) 95%
Weight 27KG
Dimension (L X W X H) 381 X 279 X 355 mm
MRP ( Inclusive of all Taxes ) Rs. 34,009
Discounted Price ( Inclusive of all Taxes ) Rs. 31,600

 

3KVA 48V Gamma PCU

 

Description Particulars
Solar PCU Capacity 3KVA 48V
Input Voltage Range (min-max) 80-230 VDC
Maximum PV Power Recommended 3KW
Types of Charger PWM with MPPT
Charge Controller Peak Efficiency 95%
Battery Low Buzzer 10.2V
Battery Low Cut 10.0V
Battery High Cut 15.5V
Battery Charging Voltage by SPV 14.5V
Battery Charging Current by SPV 18A
Battery Charging Voltage by GRID 14.2V
Battery Charging Current by GRID 10A
Grid Low Cut Voltage ( IT Load Disable/Enable) 120/175V
Grid High Cut Voltage ( IT Load Disable/Enable) 280/255V
Inverter Nominal Output Voltage 230VAC
Output Supply Phase 1 phase, 3 wire
Output Waveform Sine wave
Nominal Frequency 50.0 HZ
Load Current 9.1 A
Inverter Peak Efficiency >88%
Protections Overload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display Parameters Battery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
Switches Reset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
Indications System ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing) 95%
Weight 39KG
Dimension (L X W X H) 457 X 254 X 431 mm
MRP ( Inclusive of all Taxes ) Rs. 46,256
Discounted  Price ( Inclusive of all Taxes ) Rs. 42,979

5KVA 48V Gamma PCU

Description Particulars
Solar PCU Capacity 5KVA 48V
Input Voltage Range (min-max) 80-230 VDC
Maximum PV Power Recommended 5KW
Types of Charger PWM with MPPT
Charge Controller Peak Efficiency 95%
Battery Low Buzzer 10.2V
Battery Low Cut 10.0V
Battery High Cut 15.5V
Battery Charging Voltage by SPV 14.5V
Battery Charging Current by SPV 18A
Battery Charging Voltage by GRID 14.2V
Battery Charging Current by GRID 10A
Grid Low Cut Voltage ( IT Load Disable/Enable) 120/175V
Grid High Cut Voltage ( IT Load Disable/Enable) 280/255V
Inverter Nominal Output Voltage 230VAC
Output Supply Phase 1 phase, 3 wire
Output Waveform Sine wave
Nominal Frequency 50.0 HZ
Load Current 15.2 A
Inverter Peak Efficiency >88%
Protections Overload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display Parameters Battery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
Switches Reset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
Indications System ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing) 95%
Weight 55KG
Dimension (L X W X H) 457 X 254 X 431 mm
MRP ( Inclusive of all Taxes ) Rs. 66,517
Discounted  Price ( Inclusive of all Taxes ) Rs. 61,808

5KVA 96V Gamma PCU

Description Particulars
Solar PCU Capacity 5KVA 96V
Input Voltage Range (min-max) 160-400  VDC
Maximum PV Power Recommended 5KW
Types of Charger PWM with MPPT
Charge Controller Peak Efficiency 95%
Battery Low Buzzer 10.2V
Battery Low Cut 10.0V
Battery High Cut 15.5V
Battery Charging Voltage by SPV 14.5V
Battery Charging Current by SPV 18A
Battery Charging Voltage by GRID 14.2V
Battery Charging Current by GRID 10A
Grid Low Cut Voltage ( IT Load Disable/Enable) 120/175V
Grid High Cut Voltage ( IT Load Disable/Enable) 280/255V
Inverter Nominal Output Voltage 230VAC
Output Supply Phase 1 phase, 3 wire
Output Waveform Sine wave
Nominal Frequency 50.0 HZ
Load Current 15.2 A
Inverter Peak Efficiency >88%
Protections Overload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse
Display Parameters Battery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status
Switches Reset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration)
Indications System ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable*
Max Relative Humidity @25*C (non condensing) 95%
Weight 55KG
Dimension (L X W X H) 457 X 254 X 431 mm
MRP ( Inclusive of all Taxes ) Rs. 66,517
Discounted  Price ( Inclusive of all Taxes ) Rs. 61,808

Unique Features

  • DSPic Based Pure Sine Wave Design.
  • Inbuilt rMPPT Charge Controller (30% more efficient).
  • Maximum Power Preference to Solar Energy.
  • Digital LCD (16X2) Display.
  • Priority Based Working Modes - Smart/PCU/Hybrid.
  • Reverse AC Voltage Protection.
  • Robust Design-20 years Product Life, 2-5 years of warranty.

Special Features

Solar Battery for Long Life

The solar battery fitted in gamma solar PCU feeds to it at a constant boost charging current until its voltage reaches 14.2V and the float current (which is very close to zero) then maintains this voltage above 13V. Thus reducing the float current (flowing for the longest period during the entire process) becomes zero, which ultimately results in greatly increased battery life and is fully charged simultaneously.

Extensive electronic protection

Gamma Solar PCU which ensures safety, it prevents reverse flow from battery to solar array, it provides load short circuit protection, it provides solar battery through DC fuse, overload protection, input low or high, output low / high or solar panel provides reverse protection.

Utilizes maximum power available from the solar panel

The gamma solar PCU senses the point of maximum power available in the solar panel and charges the battery with this maximum power. Therefore, at any given time the battery is charged with the maximum possible power.

LCD display

It has an LCD display for better user interface that displays battery voltage, current charge, current discharging current, output voltage, output frequency, output load percentage, input voltage, input frequency, solar voltage, solar current and solar energy.

To get nearest Dealer Number, Fill the Form

By filling above detail I am allowing Fujiyama Power Systems Pvt. Ltd. to send me related SMS