{"id":42981,"date":"2020-09-19T07:11:46","date_gmt":"2020-09-19T07:11:46","guid":{"rendered":"https:\/\/3.6.187.192\/utl\/?page_id=42981"},"modified":"2026-04-28T13:17:45","modified_gmt":"2026-04-28T07:47:45","slug":"30kva-solar-inverter","status":"publish","type":"page","link":"https:\/\/www.upsinverter.com\/utl\/solar-inverter\/30kva-solar-inverter\/","title":{"rendered":"30kVA Solar Inverter"},"content":{"rendered":"<div id=\"pl-42981\" class=\"panel-layout\">\n<div id=\"pg-42981-0\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-42981-0-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-42981-0-0-0\" class=\"so-panel widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<h2>About 30kVA Solar Inverter<\/h2>\n<p class=\"MsoNormal\">A 30kVA <a href=\"https:\/\/upsinverter.com\/utl\/solar-inverter\/\" rel=\"nofollow noopener\" target=\"_blank\">solar inverter<\/a> is a high capacity <span style=\"background: white;\">360V 3-phase solar inverter, powered with reliable, regulated and stabilized pure sine wave output. It is an <\/span>aesthetically pleasing <span style=\"background: white;\">power converting system with over 98% maximum efficiency and is suitable for all types of home appliances and commercial establishments<\/span> that require uninterrupted power supply.<\/p>\n<figure id=\"attachment_43065\" aria-describedby=\"caption-attachment-43065\" style=\"width: 2129px\" class=\"wp-caption alignnone\"><img fetchpriority=\"high\" decoding=\"async\" data-attachment-id=\"43065\" data-permalink=\"https:\/\/www.upsinverter.com\/utl\/solar-inverter\/30kva-solar-inverter\/utl-30-kva-solar-inverter\/\" data-orig-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-30-KVA-Solar-Inverter.jpg\" data-orig-size=\"2129,865\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;Pankaj&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1600865395&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"UTL 30 KVA Solar Inverter\" data-image-description=\"&lt;p&gt;UTL 30 KVA Solar Inverter&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;UTL 30 KVA Solar Inverter&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-30-KVA-Solar-Inverter-300x300.jpg\" data-large-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-30-KVA-Solar-Inverter-1024x865.jpg\" class=\"size-full wp-image-43065\" src=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-30-KVA-Solar-Inverter.jpg\" alt=\"UTL 30 KVA Solar Inverter\" width=\"2129\" height=\"865\" title=\"\" srcset=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-30-KVA-Solar-Inverter.jpg 2129w, https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-30-KVA-Solar-Inverter-800x325.jpg 800w, https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-30-KVA-Solar-Inverter-1536x624.jpg 1536w, https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-30-KVA-Solar-Inverter-2048x832.jpg 2048w\" sizes=\"(max-width: 2129px) 100vw, 2129px\" \/><figcaption id=\"caption-attachment-43065\" class=\"wp-caption-text\">UTL 30 KVA Solar Inverter<\/figcaption><\/figure>\n<p class=\"MsoNormal\"><span style=\"border: none windowtext 1.0pt; padding: 0in;\">The 30kVA solar inverter by UTL is also a high-performance power protection device that has been engineered to be energy efficient with minimum possibility of load failure. <\/span>The inverter is IP65 and IP20 protected (as per the model) alongside several other protection functions that first run the load through the photo-voltaic panels and thereafter through the grid, if available. The combination of pulse-width modulation (PWM) with MPPT controller and other multi-level technologies enable it to track the maximum power of <a href=\"https:\/\/www.upsinverter.com\/utl\/solar-panel\/\">solar panel<\/a>.<\/p>\n<p class=\"MsoNormal\"><span style=\"background: white;\">UTL\u2019s 30kVa <a href=\"https:\/\/upsinverter.com\/utl\/solar-inverter\/\" rel=\"nofollow noopener\" target=\"_blank\">solar inverter<\/a> provides a more flexible system configuration for medium and large solar power plants.<\/span> There are unbeatable features in the 30kVA solar inverter that optimizes the performance of connected <a href=\"https:\/\/www.upsinverter.com\/utl\/product-category\/batteries\/solar-battery\/\">solar battery<\/a> and enhances their expected working life<span style=\"background: white;\">. Except for the features, you will get many outstanding advantages here such as power density, modular design, easy installation and maintenance, and highly cost-effective. <\/span>The 30kVA UTL solar inverter is worth every penny invested in it because of its high performance and durability.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-42981-1\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-42981-1-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-42981-1-0-0\" class=\"so-panel widget_sow-editor panel-first-child panel-last-child\" data-index=\"1\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<h2>UTL 30kVA Solar Inverter Range<\/h2>\n<table>\n<tbody>\n<tr>\n<td width=\"270\"><strong>Models<\/strong><\/td>\n<td width=\"174\"><strong>MRP ( Inclusive of all Taxes )<\/strong><\/td>\n<td width=\"180\"><strong>Discounted Price ( Inclusive of all Taxes )<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"270\">30kVA\/3 Phase String Solar Inverter<\/td>\n<td width=\"174\">Rs. <del>2,30,000.00<\/del><\/td>\n<td width=\"180\">Rs. 1,77,942.00<\/td>\n<\/tr>\n<tr>\n<td width=\"270\">30kVA\/360V Star Online Solar PCU<\/td>\n<td width=\"174\">Rs. <del>4,81,140.00<\/del><\/td>\n<td width=\"180\">Rs. 4,24,122.00<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-42981-2\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-42981-2-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-42981-2-0-0\" class=\"so-panel widget_sow-editor panel-first-child panel-last-child\" data-index=\"2\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<h2>30kVA On-Grid String Solar Inverter (3 Phase)<\/h2>\n<figure id=\"attachment_43080\" aria-describedby=\"caption-attachment-43080\" style=\"width: 481px\" class=\"wp-caption alignnone\"><img decoding=\"async\" data-attachment-id=\"43080\" data-permalink=\"https:\/\/www.upsinverter.com\/utl\/solar-inverter\/2kva-solar-inverter\/utl-on-grid-solar-inverter-2\/\" data-orig-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-On-Grid-Solar-Inverter.png\" data-orig-size=\"481,500\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;0&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"50kVA On-Grid String Solar Inverter (3 Phase)\" data-image-description=\"&lt;p&gt;50kVA On-Grid String Solar Inverter (3 Phase)&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;50kVA On-Grid String Solar Inverter (3 Phase)&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-On-Grid-Solar-Inverter-300x300.png\" data-large-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-On-Grid-Solar-Inverter.png\" class=\"size-full wp-image-43080\" src=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/UTL-On-Grid-Solar-Inverter.png\" alt=\"30kVA On-Grid String Solar Inverter (3 Phase)\" width=\"481\" height=\"500\" title=\"\"><figcaption id=\"caption-attachment-43080\" class=\"wp-caption-text\">30kVA On-Grid String Solar Inverter (3 Phase)<\/figcaption><\/figure>\n<table>\n<tbody>\n<tr>\n<td width=\"312\"><strong>Particular<\/strong><\/td>\n<td width=\"312\"><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Model<\/td>\n<td width=\"312\">UTL 30 GT<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">System Rating<\/td>\n<td width=\"312\">30kVA &#8211; 3 Phase<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Max. DC Power<\/td>\n<td width=\"312\">39kW<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Max. DC Voltage\/Nominal DC Voltage<\/td>\n<td width=\"312\">1000V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">MPPT Voltage Range<\/td>\n<td width=\"312\">250V &#8211; 950V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Full Load Voltage Range<\/td>\n<td width=\"312\">400V-800V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Normal DC Voltage<\/td>\n<td width=\"312\">620V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Min.\/Start DC Voltage<\/td>\n<td width=\"312\">200V &#8211; 250V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">No. of MPP Trackers<\/td>\n<td width=\"312\">3<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Strings as per MPP Tracker<\/td>\n<td width=\"312\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Max. Input Current per MPP Tracker<\/td>\n<td width=\"312\">26A<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Normal AC Output Power<\/td>\n<td width=\"312\">30kW<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Max. AC Output Power<\/td>\n<td width=\"312\">33kW<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Normal AC Voltage<\/td>\n<td width=\"312\">400V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">AC Voltage Range<\/td>\n<td width=\"312\">400V \u00b1 20%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Normal AC Grid Frequency<\/td>\n<td width=\"312\">50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">AC Grid Frequency Range<\/td>\n<td width=\"312\">50\/60Hz (\u00b1 5Hz)<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Rated Output Current<\/td>\n<td width=\"312\">44A<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Max. Output Current<\/td>\n<td width=\"312\">48A<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">THDI<\/td>\n<td width=\"312\">&lt;3%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">AC Connection<\/td>\n<td width=\"312\">3W+N+PE\/3W+P E<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Topology<\/td>\n<td width=\"312\">Transformerless<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Maximum Efficiency<\/td>\n<td width=\"312\">98.3%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Euro-eta<\/td>\n<td width=\"312\">98.0%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">All-Pole Fault Current Monitoring Unit<\/td>\n<td width=\"312\">Yes<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Ground Fault Monitoring<\/td>\n<td width=\"312\">Yes<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Operating Temperature Range<\/td>\n<td width=\"312\">-25\u00b0C to +60\u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Noise Emission<\/td>\n<td width=\"312\">&lt;40dB<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Protection Rating<\/td>\n<td width=\"312\">IP65<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">LCD Display<\/td>\n<td width=\"312\">Yes<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Cooling Concept<\/td>\n<td width=\"312\">Convection<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Interfaces<\/td>\n<td width=\"312\">RS485\/Wi-Fi<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Dimension<\/td>\n<td width=\"312\">636mmX958mmX260mm<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Weight<\/td>\n<td width=\"312\">61kG<\/td>\n<\/tr>\n<tr>\n<td width=\"312\"><strong>MRP ( Inclusive of all Taxes )<\/strong><\/td>\n<td width=\"312\"><strong>Rs. <del>2,30,000.00<\/del><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"312\"><strong>Discounted Price ( Inclusive of all Taxes )<\/strong><\/td>\n<td width=\"312\"><strong>Rs. 1,77,942.00<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Silent Features<\/h3>\n<ul>\n<li>Transformer-less inverter for better compatibility.<\/li>\n<li>Low harmonic current distortion (THDi&lt;3%).<\/li>\n<li>IP65 certified solar product by UTL.<\/li>\n<li>Comes with Onboard SPDs for DC &amp; AC sides.<\/li>\n<li>Supportable for Wi-Fi and monitoring applications.<\/li>\n<li>Manufactured with multiple protection levels.<\/li>\n<li>5 years standard warranty for better reliability.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-42981-3\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-42981-3-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-42981-3-0-0\" class=\"so-panel widget_sow-editor panel-first-child panel-last-child\" data-index=\"3\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<h2>30kVA\/360V Star Online Solar PCU<\/h2>\n<figure id=\"attachment_43090\" aria-describedby=\"caption-attachment-43090\" style=\"width: 1001px\" class=\"wp-caption alignnone\"><img decoding=\"async\" data-attachment-id=\"43090\" data-permalink=\"https:\/\/www.upsinverter.com\/utl\/solar-inverter\/30kva-solar-inverter\/star-online-solar-pcu-3\/\" data-orig-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU.jpg\" data-orig-size=\"1001,1000\" data-comments-opened=\"1\" data-image-meta=\"{&quot;aperture&quot;:&quot;0&quot;,&quot;credit&quot;:&quot;Pankaj&quot;,&quot;camera&quot;:&quot;&quot;,&quot;caption&quot;:&quot;&quot;,&quot;created_timestamp&quot;:&quot;1600867081&quot;,&quot;copyright&quot;:&quot;&quot;,&quot;focal_length&quot;:&quot;0&quot;,&quot;iso&quot;:&quot;0&quot;,&quot;shutter_speed&quot;:&quot;0&quot;,&quot;title&quot;:&quot;&quot;,&quot;orientation&quot;:&quot;0&quot;}\" data-image-title=\"60kVA Star Online PCU\" data-image-description=\"&lt;p&gt;60kVA Star Online PCU&lt;\/p&gt;\n\" data-image-caption=\"&lt;p&gt;60kVA Star Online PCU&lt;\/p&gt;\n\" data-medium-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU-300x300.jpg\" data-large-file=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU.jpg\" class=\"size-full wp-image-43090\" src=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU.jpg\" alt=\"30kVA\/360V Star Online Solar PCU\" width=\"1001\" height=\"1000\" title=\"\" srcset=\"https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU.jpg 1001w, https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU-300x300.jpg 300w, https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU-100x100.jpg 100w, https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU-800x799.jpg 800w, https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU-150x150.jpg 150w, https:\/\/d3nut88kxhmnud.cloudfront.net\/2020\/09\/STAR-ONLINE-SOLAR-PCU-768x768.jpg 768w\" sizes=\"(max-width: 1001px) 100vw, 1001px\" \/><figcaption id=\"caption-attachment-43090\" class=\"wp-caption-text\">30kVA\/360V Star Online Solar PCU<\/figcaption><\/figure>\n<table>\n<tbody>\n<tr>\n<td width=\"312\"><strong>Particulars<\/strong><\/td>\n<td width=\"312\"><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Power Rating<\/td>\n<td width=\"312\">30kVA\/360V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Voltage Range<\/td>\n<td width=\"312\">400V\u00b120% Three-phase four-wire<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Frequency<\/td>\n<td width=\"312\">50Hz\u00b110%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Power Factor<\/td>\n<td width=\"312\">0.94<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Charger Topology<\/td>\n<td width=\"312\">Buck<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Connection Type<\/td>\n<td width=\"312\">Terminal Block<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Normal PV Power<\/td>\n<td width=\"312\">30kW<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Voc (min-max)<\/td>\n<td width=\"312\">540V \u2013 810V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Vmp<\/td>\n<td width=\"312\">430V &#8211; 730V<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Switching Device<\/td>\n<td width=\"312\">IGBT<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Switching Freq.<\/td>\n<td width=\"312\">16KHz<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">No. of Charger Controller<\/td>\n<td width=\"312\">One<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Type of Charger<\/td>\n<td width=\"312\">PWM with MPPT<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Peak Ef\ufb01ciency (DC-DC)<\/td>\n<td width=\"312\">96%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Output Voltage<\/td>\n<td width=\"312\">220V\/260V \u00b11%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Output Load Current<\/td>\n<td width=\"312\">104.3A<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Output Ef\ufb01ciency (AC \u2013 AC)<\/td>\n<td width=\"312\">&gt;90%@Full Load<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Output Frequency<\/td>\n<td width=\"312\">50Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Waveform<\/td>\n<td width=\"312\">Pure Sine Wave<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Transient response<\/td>\n<td width=\"312\">&lt;8 (10% &#8211; 90% Linear Load)<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Voltage Harmonics<\/td>\n<td width=\"312\">&lt;3% (Linear Load)<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Crest Factor<\/td>\n<td width=\"312\">3:1<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Voltage Regulation<\/td>\n<td width=\"312\">\u00b11%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Frequency Regulation<\/td>\n<td width=\"312\">\u00b10.05Hz<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Alarm<\/td>\n<td width=\"312\">Battery Low, Battery High, Overload<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">LEDs<\/td>\n<td width=\"312\">UPS ON, CHG ON, Input R\/Y\/B High &amp; low, Output Low-High, Overload, Fault, Battery Low\/High, SPV Low\/High, SPV CHG ON<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Protections<\/td>\n<td width=\"312\">Output Overvoltage\/Under-voltage,Overload, Output Short-circuit,<\/p>\n<p>Battery Overvoltage\/under voltage,<\/p>\n<p>SPV Under Voltage\/ Over Voltage,<\/p>\n<p>Input Under-Voltage\/Over Voltage<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Transfer Time<\/td>\n<td width=\"312\">0 msec<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Extended Battery Charging<\/td>\n<td width=\"312\">Optional<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Caster Wheels<\/td>\n<td width=\"312\">Yes<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Operating Environment<\/td>\n<td width=\"312\">0-50\u00b0 C<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Operating Relative Humidity<\/td>\n<td width=\"312\">(5%-95%) Non-condensed<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Storage Environment<\/td>\n<td width=\"312\">0-75\u00b0 C<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Storage Relative Humidity<\/td>\n<td width=\"312\">0-95%<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Degree of Protection<\/td>\n<td width=\"312\">IP20<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Remote Monitoring<\/td>\n<td width=\"312\">Ethernet (Optional)<\/td>\n<\/tr>\n<tr>\n<td width=\"312\">Dimension (LXWXH)<\/td>\n<td width=\"312\">990x660x889 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"312\"><strong>MRP ( Inclusive of all Taxes )<\/strong><\/td>\n<td width=\"312\"><strong>Rs.<del>4,81,140.00<\/del><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"312\"><strong>Discounted Price ( Inclusive of all Taxes )<\/strong><\/td>\n<td width=\"312\"><strong>Rs.4,24,122.00<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Silent Features<\/h3>\n<ul>\n<li>Short circuit, input under\/over-voltage protection.<\/li>\n<li>Intelligent charge sharing.<\/li>\n<li>DSP based design Pure Sinewave<\/li>\n<li>Built-in rMPPT charge controller.<\/li>\n<li>Lightning, surge protection by SPD.<\/li>\n<li>Thermal Protection.<\/li>\n<li>Maximum Preference for Solar Power.<\/li>\n<li>Ethernet-based monitoring.<\/li>\n<li>Noiseless in operation.<\/li>\n<li>Robust Design &#8211; 20 years of Product life.<\/li>\n<li>AC and DC Parameter Configurable from LCD.<\/li>\n<li>DC- Charging Voltage Battery Charging Current, Battery Low Cut\/High Cut.<\/li>\n<li>High Surge Capability (up to 300%) for starting heavy load.<\/li>\n<li>High Efficiency &amp; High Reliability.<\/li>\n<li>Configurable Priority.\n<ul>\n<li>Solar\/Battery\/Grid<\/li>\n<li>Solar\/Grid\/Battery<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-42981-4\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-42981-4-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-42981-4-0-0\" class=\"so-panel widget_sow-editor panel-first-child panel-last-child\" data-index=\"4\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n<h2>FAQs<\/h2>\n<h3>How much power does a 30kVA solar inverter produce?<\/h3>\n<p>A 30kVA <a href=\"https:\/\/upsinverter.com\/utl\/solar-inverter\/\" rel=\"nofollow noopener\" target=\"_blank\">solar inverter<\/a> is genuinely used with a 30kW solar system and a 30kW solar system can produce up to 120 units per day. So accordingly, you will get 120 units through 30kVA inverter in a day.<\/p>\n<h3>What is the price of a 30kVA commercial solar inverter?<\/h3>\n<p>The actual price depends upon the model that you will choose. But the price range of 30kVA solar inverter lies between Rs.1,77,942 to Rs.3,77,610.<\/p>\n<h3>How many batteries do I need with 30kVA solar inverter?<\/h3>\n<p>Batteries are needed only if you are installing off-grid solar systems or hybrid solar systems. If you have these types of solar systems then you will need at least 30 nos. of UTL solar batteries.<\/p>\n<h3>Can a 30kVA solar inverter run my 2 solar water pumps simultaneously?<\/h3>\n<p>Yes, it can run 2 solar water pumps at the same time if the load limit is beyond 30kW or 30,000 watts.<\/p>\n<h3>What is the average payback period of UTL\u2019s 30kVA online solar PCU?<\/h3>\n<p>The average payback period of UTL 30kVA online solar PCU is 3 to 5 years. You will get a full ROI within 5 years.<\/p>\n<h3>What is the warranty period for this solar inverter?<\/h3>\n<p>UTL offers 2-year warranty on 30kVA online solar PCU and 5 years warranty on 30kVA grid-tie solar inverter.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div id=\"pg-42981-5\" class=\"panel-grid panel-no-style\">\n<div id=\"pgc-42981-5-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-42981-5-0-0\" class=\"so-panel widget_sow-editor panel-first-child panel-last-child\" data-index=\"5\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<h3 class=\"widget-title\">To get UTL Dealer Number at your phone please fill the Form<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>About 30kVA Solar Inverter A 30kVA solar inverter is a high capacity 360V 3-phase solar inverter, powered with reliable, regulated [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":115881,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-42981","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/pages\/42981","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/comments?post=42981"}],"version-history":[{"count":7,"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/pages\/42981\/revisions"}],"predecessor-version":[{"id":131587,"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/pages\/42981\/revisions\/131587"}],"up":[{"embeddable":true,"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/pages\/115881"}],"wp:attachment":[{"href":"https:\/\/www.upsinverter.com\/utl\/wp-json\/wp\/v2\/media?parent=42981"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}